 The GenesysTM family of programmable power supplies sets a new standard for flexible, reliable, AC/DC power systems in OEM, Industrial and Laboratory applications.
Features include:
* Highest Power Density available 1500W in 1U * Wide Range Input 85 - 265Vac Continuous, single phase, 47/63Hz * Active Power Factor Correction 0.99 * Output up to 600V, Current up to 200A * Built in RS232/RS485 Interface * Software Calibration * Last Setting Memory * High Resolution 16 bits ADCs & DACs * Reliable Encoders for Voltage and Current Adjustment * Constant Voltage/Constant Current auto crossover * Parallel Operation with Active Current Sharing * Independent Remote ON/OFF and Remote Enable/Disable * External Analog Programming and Monitoring * Reliable Modular and SMT Design * 19" Rack Mounted ATE and OEM applications * Five Year Warranty * Optional Isolated Analog Programming and Monitoring * Optional GPIB (SCPI) Interface * LabView(R) drivers ( LabView(R) is registered trademark of National Instruments Corporation )
Worldwide Safety Agency Approvals CE Mark for LVD and EMC Regulation
Applications
GenesysTM power supplies have been designed to meet the demands of a wide variety of applications.
Test and Measurement
Last setting memory simplifies test design and requires no battery backup. Built in RS232/RS485 gives maximum system flexibility along with 0-5V and 0-10V, selectable analog programming Wide range of available inputs allows testing of many different devices.
Semiconductor Burn-in
Safe Start may be enabled to restart at zero output to protect load. Wide range input (85-265VAC) with Active Power Factor correction rides through input transients easily.
Component Test
High power density, zero stacking and single wire parallel operation give maximum system flexibility
Laser Diode
OVP is directly set on Voltage Meter, assuring accurate protection settings. Current Limit Fold Back assures load is protected from current surges.
Heater Supplies
Smooth, reliable encoders enhance front panel control. Remote analog programming is user selectable 0-5V or 0-10V.
RF Amplifiers and Magnets
Robust design assures stable operation under a wide variety of loads. Excellent linearity in voltage and current mode.
1|GenesysTM 750W/1500W-1U
Front Panel Description
1. AC On/Off 2. Air Intake allows zero stacking for maximum system flexibility and power density 3. Reliable encoder controls Output Voltage and sets Address. 4. Volt Meter shows Output Voltage and directly displays OVP, UVL and Address settings. 5. Amp Meter also displays baud rate. 6. Reliable encoder controls Output Current and sets baud rate. 7. Function/Status LED's * Alarm * Fine Control * Preview Settings * Foldback Mode * Remote Mode * Output On
8. Pushbuttons allow flexible user configuration Coarse and Fine Voltage and Current Adjustment of Output Preview Settings and Set Voltage while in Current Mode or with Output OFF Set OVP and UVL Limits Set Current Foldback Local/Remote Mode and select Address and Baud Rate Output ON/OFF and Auto Start/Safe Start Mode
Rear Panel Description
1. 2. 3. 4. 5. 6. 7. 8.
Remote/Local Output Voltage Sense Connections DIP Switches select 0-5V or 0-10V Programming and other functions. DB25 (Female) connector allows (Non-isolated) Analog Program and Monitor as well as other functions. RS485 Out to other Genesys Power Supplies RS232/RS485 IN Remote Serial Programming Output Terminals are rugged bus bars for 6-60V Output, higher output voltage models have terminal block connector. Exit air assures reliable operation when zero stacked Wide-Range Input 85-265VAC continuous, 47/63Hz with Active Power Factor Correction (0.99) AC Input Connector 750W: IEC320, 1500W: Screw terminal Model Shown 9. Position for Optional Isolated Analog Programming or GPIB Digital Interface model shown
|2
Genesys TM 750W/1500W Specifications
1.0 MODEL 1.Rated output voltage(*1) 2.Rated Output Current(*2) 3.Rated Output Power 4.Efficiency at 100/200Vac (*3) 1.0 MODEL 1.Rated output voltage (*1) 2.Rated Output Current (*2) 3.Rated Output Power 1.1 CONSTANT VOLTAGE MODE 1.Max.line regulation ( 0.01% of Vo+ 2mV )(*4) 2.Max load regulation ( 0.01% of Vo+2mV )(*5) 3.Ripple and noise p-p 20MHz 4.Ripple r.m.s 5Hz~1MHz 5.Remote sense compensation/line 6.Temp. coefficient 7.Up-prog. response time, 0~Vomax 8.Down-prog response time full-load 9.Down-prog response time no-load 10.Transient response time (*8) 1.2 CONSTANT CURRENT MODE 1.Max.line regulation (0.01% of Io+ 2mA)(*4) 2.Max.load regulation (0.01% of Io+5mA)(*6) 3.Ripple r.m.s 5Hz~1MHz . (*7) 1.Max.line regulation (0.01% of Io+ 2mA)(*4) 2.Max.load regulation (0.01% of Io+5mA)(*6) 3.Ripple r.m.s 5Hz~1MHz .(*7) 4.Temp. coefficient 1.3 PROTECTIVE FUNCTIONS 1. OCP 2. OCP Foldback 3. OVP type 4. OVP trip point 5. Over Temp. Protection 1.4 ANALOG PROGRAMMING AND MONITORING 1.Vout Voltage Programming 2.Iout Voltage Programming 3.Vout Resistor Programming 4.Iout Resistor Programming 5.On/Off control (rear panel) 6.Output Current monitor 7.Output Voltage monitor 8.Power Supply OK signal 9. CV/CC indicator 10. Enable/Disable 1.5 FRONT PANEL 1.Control functions GEN V A W % GEN V A W 6-200 6 200 1200 77/80 6-100 6 100 600 8-180 12.5-120 20-76 8 12.5 20 180 1440 78/81 8-90 8 90 720 120 1500 81/84 76 1520 83/86 30-50 30 50 1500 83/86 30-25 30 25 750 40-38 40 38 1520 84/88 60-25 60 25 1500 84/88 80-19 100-15 80 100 19 1520 84/88 15 1500 84/88 150-10 150 10 1500 84/88 150-5 150 5 750 300-5 300 5 1500 83/87 600-2.6 600 2.6 1560 83/87
750W
X X X X X X X X X X X X X X X X X X
1500W X X X X X
12.5-60 20-38 12.5 20 60 38 750 760
40-19 60-12.5 80-9.5 100-7.5 40 60 80 100 19 12.5 9.5 7.5 760 750 760 750
300-2.5 600-1.3 300 600 2.5 1.3 750 780 62 62 300 60 5
mV 2.6 2.8 3.3 4 5 6 8 10 12 17 32 mV 2.6 2.8 3.3 4 5 6 8 10 12 17 32 mV 60 60 60 60 60 60 60 80 100 80 125 mV 8 8 8 8 8 8 8 8 8 10 25 V 1 1 1 1 1.5 2 3 4 5 5 5 PPM/C 100PPM/C from rated output voltage,following 30 minutes warm up mS 80mS , N.L/F.L , resistive load 150mS , N.L/F.L , resistive load mS 10 50 80 150 mS 500 600 700 800 900 1000 1100 1200 1500 2000 2500 Less than 1mSec for models up to and including 100V. 2msec for models above 100V mA 12 5.8 4.5 11 8 3.9 3.25 2.95 15 7.5 mA 14 11 8.8 6.9 6.25 5.95 mA 200 120 76 63 38 180 48 29 2 2 mA 2 2 2 2 2 2 mA 5 5 5 5 5 5 5 5 mA 400 152 125 360 240 95 75 57 PPM/C 100PPM/C from rated output voltage,following 30 minutes warm up 2.75 5.75 23 2 5 45 2.5 5.5 18 2 5 35 2.25 5.25 13 2 5 25
4000
X X X X X X X X X X
2.13 5.13 8 2 5 12
X X X X X X X X X X X X X X X X X X X X X X X X X 750W X X X
X X X X X X X X X X X X X X X X X X X X X X X X X X X X 1500W X X X
0~105% Constant Current Output shut down when power supply change from CV to CC. User selectable. Inverter shut-down, manual reset by AC input recycle or by OUT button 0.5~7.5V 0.5~10V 1~15V 1~24V 2~36V 2~44V 5~66V 5~88V 5~110V 5~165V 5~330V 5~660V User selectable , latched or non latched 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:+/-0.5% of rated Vout. 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:+/-1% of rated Iout. 0~100%, 0~5/10Kohm full scale,user select.,Accuracy and linearity:+/-1% of rated Vout. 0~100%, 0~5/10Kohm full scale,user select. Accuracy and linearity:+/-1.5% of rated Iout. By electrical. Voltage: 0~0.6V/2~15V,or dry contact ,user selectable logic 0~5V or 0~10V , accuracy:1% , user selectable 0~5V or 0~10V ,accuracy:1% ,user selectable 5V-OK, 0V-Fail 500ohm impedance CV: TTL high (4~5V) source: 10mA, CC: TTL low (0~0.4V):10mA Dry contact. Open:off , Short: on. Max. voltage at Enable/Disable in: 6V Vout/ Iout manual adjust by separate encoders (coarse and fine adjustment selectable) OVP/UVL manual adjust by Volt. Adjust encoder AC on/off, Output on/off, Re-start modes (auto, safe), Foldback control (CV to CC), Go to local control Address selection by Voltage (or current) adjust encoder. No of addresses:31 RS232/485 and IEEE488.2 selection by IEEE enable switch and DIP switch Baud rate selection: 1200,2400,4800,9600 and 19,200 bps Voltage 4 digits , accuracy: 0.5%+/-1 count Current 4 digits, accuracy: 0.5%+/-1 count Voltage, Current, Alarm, Fine, Preview, Foldback, Local, Output On
2.Display 3.Indications
1.6 Interface RS232&RS485 or Optional GPIB Interface
V Model Remote Voltage Programming (16 bit) Resolution (0.012% of Vomax) mV Accuracy (0.05%Vomax+0.05% of Vo Actual Output) mV Remote Current Programming (16 bit) Resolution (0.012% of Iomax) Accuracy (0.05% of Iomax+0.05% of Io Actual Output) Resolution (0.012% of Iomax) Accuracy (0.05% of Iomax+0.05% of Io Actual Output) 6 0.72 6.0 8 0.96 8.0 12.5 1.50 12.5 20 2.40 20 30 3.60 30 40 4.80 40 60 7.2 60 80 9.6 80 100 12 100 150 18 150 300 36 300 600 72 600
mA mA mA mA
12 10 24 20
10.8 9 21.6 18
7.2 6 14.4 12
4.56 3.8 9.12 7.6
3.0 2.5 6 5
2.28 1.9 4.56 3.8
1.50 1.25 3.0 2.5
1.14 0.95 2.28 1.9
0.90 0.75 1.80 1.50
0.60 0.5 1.20 1
0.30 0.25 0.60 0.5
0.16 0.13 0.32 0.26
X X X X
Readback Voltage Resolution (0.012% of Vomax) mV Accuracy (0.1%Vomax+0.1% of Vo Actual Output) mV Readback Current Resolution (0.012% of Iomax ) Accuracy (0.1% of Iomax+0.3% of Io Actual Output) Resolution (0.012% of Iomax ) Accuracy (0.1% of Iomax+0.3% of Io Actual Output) OVP Programming Resolution (0.1% of Vomax) Accuracy (1% of Vomax)
0.72 12
0.96 16
1.50 25
2.40 40
3.60 60
4.80 80
7.2 120
9.6 160
12 200
18 300
36 600
72 1200
X X
X X
mA mA mA mA
12 400 24 800
10.8 360 21.6 720
7.2 240 14.4 480
4.56 152 9.12 304
3.0 100 6 200
2.28 76 4.56 152
1.50 50 3.0 100
1.14 38 2.28 76
0.9 30 1.80 60
0.60 20 1.20 40
0.30 10 0.60 20
0.16 5.2 0.32 10.4
X X X X
mV mV
6 60
8 80
12 125
20 200
29 300
39 400
59 600
78 800
98 1000
146 1500
293 3000
586 6000
X X
X X
*1: Minimum voltage is guaranteed to maximum 0.2% of Vomax. *3: At maximum output power. *5: From No-load to Full-load, constant input voltage. *2: Minimum current is guaranteed to maximum 0.4% of Iomax. *4: 85~132Vac or 170~265Vac, constant load. *6: For load voltage change, equal to the unit voltage rating, constant input voltage. *7: For 6V models the ripple is measured at 2~6V output voltage and full output current. For other models, the ripple is measured at 10~100% output voltage and full output current. *8: Time for the output voltage to recover within 0.5% of its rated for a load change 10~90% of rated output , Output set-point:10~100%. Accuracy -Values have been calculated at Vomax & Io max
3|GenesysTM 750W/1500W-1U
General Specifications GenesysTM 750W/1500W
2.1 INPUT CHARACTERISTICS 1. Input voltage/freq. (*1) 2. Power Factor 3. EN61000-3-2,3 compliance 4. Input current 100/200Vac 5. Inrush current 100/200Vac 6. Hold-up time 2.2 POWER SUPPLY CONFIGURATION 1. Parallel Operation 2. Series Operation 2.3 ENVIRONMENTAL CONDITIONS 1. Operating temp 2. Storage temp 3. Operating humidity 4. Storage humidity 5. Vibration 6. Shock 7. Altitude 2.4 EMC 1.Applicable standards: 2.ESD 3.Fast transients 4.Surge immunity 5.Conducted immunity 6.Radiated immunity 7.Conducted emission 8.Radiated emission 9.Voltage dips 10. Conducted emission 11. Radiated emission 2.5 SAFETY 1.Applicable standards:
85~265Vac continuous, 47~63Hz, single phase 0.99 @100/200Vac, rated output power. Complies with EN61000-3-2 class A and EN61000-3-3 at 20~100% output power. 750W :10.5A / 5A, 1500W :21A / 11A 750W :Less than 25A, 1500W :Less than 50A More than 20mS , 100Vac , at 100% load.
Up to 4 units in master/slave mode with single wire current balance connection Up to 2 units. with external diodes. 600V Max to Chassis ground 0~50 C, 100% load. -20~70C 30~90% RH (no condensation). 10~95% RH (no condensation). MIL-810E, method 514.4 , test cond. I-3.3.1 . The EUT is fixed to the vibrating surface. Less than 20G , half sine , 11mSec. Unit is unpacked. Operating: 10000ft (3000m) , Non operating: 40000ft (12000m).
EN55024 IEC1000-4-2. Air-disch.-8KV, contact disch.-4KV IEC1000-4-4. 2KV IEC1000-4-5. 1KV line to line, 2KV line to ground IEC1000-4-6, 3V IEC1000-4-3, 3V/m EN55022B,FCC part 15J-B,VCCI-2 EN55022A,FCC part 15-A,VCCI-1 EN61000-4-11 EN55022B, FCC part 15-B, VCCI-2. EN55022A, FCC part 15-A, VCCI-1.
2.Withstand voltage
3.Insulation resistance 2.6 MECHANICAL CONSTRUCTION 1. Cooling 2. Dimensions (WxHxD) 3. Weight 4. AC Input connector 5.Output connectors 2.7 RELIABILITY SPECS 1. Warranty
CE Mark, UL60950,EN60950 listed. Vout<60V:Output is SELV , IEEE/Isolated analog are SELV. 60Forced air flow: from front to rear. No ventilation holes at the top or bottom of the chassis Variable fan speed. W: 422.8mm, H: 43.6mm, D: 432.8mm (excluding connectors, encoders, handles etc..) 750W: 7Kg (15.4 Lbs) 1500W: 8.5Kg (18.7 Lbs) 750W: AC Inlet IEC320. 1500W: screw terminal block, Phoenix P/N: FRONT-4-H-7.62 , with strain relief 6V to 60V models: bus-bars (hole O 8.5mm). 80V to 600V models :terminal block ,Phoenix P/N: FRONT-4-H-7.62
5 years.
*1: For cases where conformance to various safety standards (UL, IEC etc.) is required, to be described as 100-240Vac (50/60Hz).
Outline Drawing GenesysTM 750W/1500W Units
NOTE
1. PLUG CONNECTORS INCLUDED WITH THE POWER SUPPLY 2. CHASSIS SLIDES MOUNTING HOLES #10-32 MARKED "A" GENERAL DEVICES P/N: CC301-00-S160 OR EQUIVALENT
|4
GenesysTM Power Parallel and Series Configurations
Parallel operation - Master/ Slave:
Active current sharing allows up to 4 units to be connected in an auto parallel configuration for four times the output power.
Series operation
Up to two units may be connected in series to increase the output voltage or to provide bipolar output. (Max 600V to Chassis Ground)
Remote Programming via RS232&RS485 Interface
Standard Serial Interface allows chain control of up to 31 power supplies on the same bus with built in RS232&485 Interface
Programming Options (Factory installed)
Digital Programming via IEEE Interface
* IEEE 488.2 Compliant * Program Voltage * Measure Voltage * Over Voltage setting and shutdown * Error and Status Messages
P/N: IEEE
* SCPI Compliant * Program Current * Measure Current * Current Foldback shutdown
Isolated Analog Programming
Four Channels to Program and Monitor Voltage and Current Isolation allows operation with floating references and difficult electrical environments. Choose between programming with Voltage or Current. Connection via Removable terminal block P/N: Phoenix MC1,5/8-ST-3.81
P/N: IS510 - Voltage Programming, user selectable 0-5V or 0-10V signal
Power supply Voltage and Current Programming accuracy +/-1% Power supply Voltage and Current Monitoring accuracy +/-1.5%
P/N: IS420 - Current Programming with 4-20mA signal
Power supply Voltage and Current Programming accuracy +/-1% Power supply Voltage and Current Monitoring accuracy +/-1.5%
5|GenesysTM 750W/1500W-1U
Power Supply Identification / Accessories How to order
GEN
Series Name
600
Output Voltage (0~600V)
Output Voltage VDC 0~6V 0~8V 0~12.5V 0~20V 0~30V 0~40V
-
2.6
Output Current (0~2.6A)
Factory Options
AC Cable option is 750W only
Option: IEEE IS510 IS420
Models 750/1500W
Model GEN6-100 GEN6-200 GEN8-90 GEN8-180 GEN12.5-60 GEN12.5-120 GEN20-38 GEN20-76 GEN30-25 GEN30-50 GEN40-19 GEN40-38 Output Current (A) 0~100 0~200 0~90 0~180 0~60 0~120 0~38 0~76 0~25 0~50 0~19 0~38 Output Power (W) 600 1200 720 1440 750 1500 760 1520 750 1500 760 1520 Model GEN60-12.5 GEN60-25 GEN80-9.5 GEN80-19 GEN100-7.5 GEN100-15 GEN150-5 GEN150-10 GEN300-2.5 GEN300-5 GEN600-1.3 GEN600-2.6
Region: E - Europe J - Japan I - Middle East U - North America
Output Voltage VDC 0~60V 0~80V 0~100V 0~150V 0~300V 0~600V Output Current (A) 0~12.5 0~25 0~9.5 0~19 0~7.5 0~15 0~5 0~10 0~2.5 0~5 0~1.3 0~2.6 Output Power (W) 750 1500 760 1520 750 1500 750 1500 750 1500 780 1560
Factory option
RS232/485 Interface built in Standard GPIB Interface Voltage Programming Isolated analog interface Current Programming Isolated analog interface
P/N
IEEE IS510 IS420
AC Cords sets (750W only)
Region Output Power AC Cords Wall Plug Power Supply Connector Europe 750W 10A/250 Vac L=2m INT'L 7/VII IEC320-C13 Japan Middle East North America 750W 750W 750W 13A/125 Vac L=2m 10A/250 Vac L=2m 13A/125 Vac L=2m SI-32 NEMA 5-15P IEC320-C13 IEC320-C13 IEC320-C13
Part Number
P/N: GEN/E
P/N: GEN/J
P/N: GEN/I
P/N : GEN/U
Accessories
1.Communication cable RS232/RS485 Cable is used to connect the power supply to the PC Controller
Mode PC Connector Communication Cable Power Supply Connector P/N RS485 DB-9F Shield Ground L=2m EIA/TIA-568A (RJ-45) GEN/485-9 RS232 DB-9F Shield Ground L=2m EIA/TIA-568A (RJ-45) GEN/232-9 RS232 DB-25F FShield Ground L=2m EIA/TIA-568A (RJ-45) GEN/232-25
Serial link cable* Chaining Power Supply to Power Supply up to 31 GEN units
Mode RS485
* Included with the power supply
Power Supply Connector EIA/TIA-568A (RJ-45)
Communication Cable Shield Ground L=50cm
P/N GEN/RJ45
|6


▲Up To Search▲   

 
Price & Availability of GEN100-15

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X